PowerStackHubSolar panels, inverters, lithium batteries, ESS cabinets, and battery management systems for global industrial buyers.
Kstar UPS Ydc3300 with Lead Acid Battery 3: 3 Phase 60kVA 80kVA 100kVA 120kVA 150kVA 200kVA
Port And Wharf Equipment

Kstar UPS Ydc3300 with Lead Acid Battery 3: 3 Phase 60kVA 80kVA 100kVA 120kVA 150kVA 200kVA

This detail page turns one product record into a narrower sourcing decision with clearer category fit, adjacent routes and RFQ-ready context.

Quote on request

Kstar | Applications and Buyer Notes

Kstar is organized as a sourcing-ready Port And Wharf Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time qu

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Vertical Site
energystoragesupplyBased on visible page data; confirm exact value in the RFQ.
Category
Solar Panels and ModulesBased on visible page data; confirm exact value in the RFQ.
Source Domain
ahtechsolar.en.made-in-china.comBased on visible page data; confirm exact value in the RFQ.
Brand
KstarBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
AC Mode
Up to 95.5%Based on visible page data; confirm exact value in the RFQ.
Altitude(m)
1000,derating required when>1000Based on visible page data; confirm exact value in the RFQ.
Application
Food and beverage processingBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Product sourcing profile

CategoryPort And Wharf Equipment
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Electrical & Electronics Power Supply & Distribution UPS Kstar UPS Ydc3300 with Lead Acid Battery 3: 3 Phase 60kVA 80kVA 100kVA 120kVA 150kVA 200kVA US$1,615.00-7,900.00 1 Piece-led product discovery for buyers looking for solar panels and modules options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: solar panels, inverters, lithium batteries, ess cabinets, and battery management systems sourcing and rfq-ready export supply platform.batterycommercialbatteriesstorage

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Kstar Ups Lead Acid Battery

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Port Wharf Equipment

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

Key specifications

Vertical Siteenergystoragesupply
CategorySolar Panels and Modules
Source Domainahtechsolar.en.made-in-china.com
Brand
Unitset
AC ModeUp to 95.5%
Altitude(m)1000,derating required when>1000
ApplicationFood and beverage processing
Battery TypeVRLA/Li-ion
Battery Voltage (Vdc)360~600
BrandKstar
Bypass Frequency Range (Hz)50/60±10%
Bypass Mode30ºC: 135% for long term;40ºC: 125% for long term;>1000%,100ms
Bypass Voltage Range (Vac)Max.voltage: 220: +25%-45%-10%-15%-20%-30%
Capacity216.000kg
Capacity (VA/W)50k/50k 60k/60k 80k/80k 100k/100k 120k/120k 150k/150k 160k/160k 180k/180k 200k/200k
CategorySolar Panels and Modules
Charging Current(Max.)(A)20 40 60
ClassificationLighting/Power
Crest Factor3:1
CustomizationAvailable
Dimension WxDxH (mm)250x828x868 442x850x1200
Dimensions442×850×1200mm
ECO ModeUp to 99%
EMCIEC/EN 62040-2
Equipment ModeCentralized Model
Feature Highlightsdigital
Harmonic Distortion (THDi)≤3% Linear load
Harmonic Distortion (THDv)≤2% with linear load;≤4% with non linear load
Humidity Range0~95% (Non condensing)
MODELYDC3350H YDC3360H YDC3380H YDC33100H YDC33120H YDC33150H YDC33160H YDC33180H YDC33200H
Matched Termsbattery, commercial, batteries, storage
Model NO.YDC33150H
Nominal Voltage (Vac)380/400/415 (3Ph+N+PE)
Operating Temperature (ºC)0~40
Operating Voltage Range (Vac)138~305 for 40% load;305~485 for 100% load
OriginChina
Output CapacityMedium Type
Output Frequency (Hz)Line mode: Synchronize with input, when the input frequency >±10% (±1%/±2%/±4%/±5% optional), output 50/60 (±0.1);Bat. mode: (50/60±0.2%)
OverloadInverter Mode ≤110% 60min,≤125% 10min, ≤150% 1min, >150% 1.2s shut down inverter ≤110% 60min, s125% 1min, >125% 1.2s shut down inverter
PerformanceIEC 62040-3: 2021, EN IEC 62040-3:2021
PhaseThree Phase
Power Factor20.99
Product TitleKstar UPS Ydc3300 with Lead Acid Battery 3: 3 Phase 60kVA 80kVA 100kVA 120kVA 150kVA 200kVA
ProtectionOvervoltage
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
SafetyIEC/EN 62040-1, IEC/EN 62477-1
Secure paymentsEvery payment you make on Made-in-China.com is protected by the platform.
Shipping Cost.
Specification442×850×1200MM
Standby TimeStandard Machine
Standby UPSSine Wave Output UPS
Storage Temperature (ºC)25-55
TrademarkKstar
Transport PackageCarton
TypeOn-line
US$1,615.00-7,900.001 Piece (MOQ)
Voltage Regulation±1%
colorblack
power50K

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Kstar UPS Ydc3300 with Lead Acid Battery 3: 3 Phase 60kVA 80kVA 100kVA 120kVA 150kVA 200kVA sourcing decision brief

This detail page turns one product record into a narrower sourcing decision with clearer category fit, adjacent routes and RFQ-ready context.

Category
Solar Panels and Modules
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Product detail to shortlist decision
Primary compare
Vertical Site, Category, Source Domain
Record focus
Kstar Ups Ydc3300 With Lead Acid Battery 3: 3 Phase 60kva 80kva 100kva 120kva 150kva 200kva
Category focus
Port And Wharf Equipment
Buyer checklist
  • Category fit: Confirm whether the product belongs to the right category and nearby application path before outreach.
  • Specification depth: Review the visible specifications and convert missing fields into a clearer RFQ requirement set.
  • Route expansion: Use adjacent category, solution and procurement routes before settling on one detail page.
How should buyers use this detail page?

Use the detail page as a product-fit checkpoint. Confirm category placement, visible specifications and adjacent sourcing paths before sending an RFQ.

What should buyers compare first?

Compare the visible specifications, category fit and the nearest application or solution routes before asking for supplier options.

PowerStackHub related sourcing paths

PowerStackHub procurement phrases

PowerStackHub project-fit checks

Application Confirm Application before comparing offers or moving the inquiry forward.
Country Confirm Country before comparing offers or moving the inquiry forward.
Capacity Confirm Capacity before comparing offers or moving the inquiry forward.
Material Confirm Material before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerStackHub related product samples

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions