PowerStackHubSolar panels, inverters, lithium batteries, ESS cabinets, and battery management systems for global industrial buyers.
New Silu UPS Uninterruptible Power Supply Cye2K Online 2000va/1600W Built-in Battery Mh12V7ah * 4, Server Voltage Regulation, Power Outage, Silent 220V
Traffic Safety Facilities

New Silu UPS Uninterruptible Power Supply Cye2K Online 2000va/1600W Built-in Battery Mh12V7ah * 4, Server Voltage Regulation, Power Outage, Silent 220V

This detail page turns one product record into a narrower sourcing decision with clearer category fit, adjacent routes and RFQ-ready context.

Quote on request

New | Applications and Buyer Notes

New is organized as a sourcing-ready Traffic Safety Facilities reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time que

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Lithium Battery SystemsBased on visible page data; confirm exact value in the RFQ.
Brand
XinsiluBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
10
Over-temperature warning Warning, battery discharge PFC or INV temperature sensoBased on visible page data; confirm exact value in the RFQ.
12
Fan failure Warning No fan speed signal detected RecoverableBased on visible page data; confirm exact value in the RFQ.
13
Mains disconnect Warning The difference between the mains voltage and the bypassBased on visible page data; confirm exact value in the RFQ.
14
EEPROM failure Warning EEPROM read and write failed UnrecoverableBased on visible page data; confirm exact value in the RFQ.
17
Inverter soft St a F t failure Turn to fault mode After inverting soft start 40sBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Product sourcing profile

CategoryTraffic Safety Facilities
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Electrical & Electronics Power Supply & Distribution UPS New Silu UPS Uninterruptible Power Supply Cye2K Online 2000va/1600W Built-in Battery Mh12V7ah * 4, Server Voltage Regulation, Power Outage, Silent 220V US$ Pieces US$ Pieces US$8PowerStackHub curates RFQ-led product discovery for buyers looking for lithium battery systems options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: solar panels, inverters, lithium batteries, ess cabinets, and battery management systems sourcing and rfq-ready export supply platform.

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Built-in Battery

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Lithium Battery Systems

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

Key specifications

CategoryLithium Battery Systems
Brand
Unitset
10Over-temperature warning Warning, battery discharge PFC or INV temperature sensor is higher than 80 degrees Celsius Recoverab ie
12Fan failure Warning No fan speed signal detected Recoverable
13Mains disconnect Warning The difference between the mains voltage and the bypass voltage is greater than 100V Recoverable
14EEPROM failure Warning EEPROM read and write failed Unrecoverable
17Inverter soft St a F t failure Turn to fault mode After inverting soft start 40s, the rated output voltage cannot be reached, or after inverting soft 2s, the inverter voltage is still less than 20V. Unrecoverable
18Inverter output overvoltage Warning, battery discharge load more than 102% Recoverable (overload less than 97%)
19Inverter output undervoltage Turn to fault mode The inverter voltage is below 130V and lasts 400ms Unrecoverable
1KVA2KVA 3KVA 1KVA 2KVA 3KVA
20Inverter short circuit Turn to fault mode The inverter voltage is less than SOV, the current is hipher than 20A, andlasts 4s Unrecoverable
22Overload lock in bypass Warning 3 times of overload transfer to bypass mode in 30 minutes Manual boot can be restored
23EPO action Warning, battery discharge Recoverable
24Maintenance switch action Warning Short circuit of CN4 terminal on control board Recoverable
26Negative power protection Turn to fault mode Inverter power is less than-2400W for 20ms, or-800W for 120ms Unrecoverable
33Inverter relay open Turn to fault mode When the inverter relay is cIosed,the difference between the inverter voltage andthe output voltage exceeds 30V for 160ms Unrecoverable
34Inverter rela short circuit y Turn to fault mode When the bypass relay is cIosed,the inverter relay is disconnected and the inverter bridge is not working the difference between the inverter voltage and the bypass voltage is less than 30V Unrecoverable
35Bypass F B I a y open Turn to fault mode When the bypass relay is cIosed,the difference between the bypass voltage and the output voltage exceeds 30V for 160ms Unrecoverable
36Bypass relay short circuit Turn to fault mode When the bypass relay and the inverter relay are disconnected,the difference etween the output voltage and the bypass voltage is less than 30V for 160ms Unrecoverable
37Input and O t U t reversed 'J p Turn to fault mode When the bypass relay and the inverter relay are disconnected,the bypass voltage is less than 20V, but the output voltage is greater than 150V Unrecoverable
39Charger short circuit Turn to fault mode The battery voltage is less than SOV and the charging current is higher than 4A Unrecoverable
66Overload fault Turn to fault mode The load exceeds the specification Unrecoverable
67Reverse battery Turn to fault mode The battery input is reversed Unrecoverable
68Model recognition error Turn to fault mode Undefined machine model Unrecoverable
73No bootloader Turn to fault mode No boot program Unrecoverable
AC Mode95%
ApplicationElectrical and power distribution
Battery Mode10min@102%-110%Ioad, 1min@110%-130%load 10s@130%-150%Ioad, 500ms@> 150 %Ioad
BrandXinsilu
Built in BatteryFour 7ah Batteries
Capacity1KW 2KW 3KW 1KW 2KW 3KW
CategoryLithium Battery Systems
Certification CertificateISO9001-ISO45001-ISO14001
Charging Currentdefault 1A
Charging Voltage13.65 x NI1 %
ClassificationLighting
Current peak ratio3:1 (Maximum)
CustomizationAvailable
DC Output72V
Emergency Time15 Minutes(Customizable)
Equipment ModeDecentralized
Fault codeEnglish meaning Related actions Trigg er condition Recovery condition
Feature Highlightsdigital
Frequency Range40-60HZ@50HZ system/50-70HZ@60HZ system
Frequency Range (battery mode)50hz+0.1 HZor60HZ+0.1 HZ
Frequency Range (synchronization range)40-60hz@50HZsystem/50-70HZ@60HZsystem
HS Code3101
Harmonic distortion2%-linear load
Inverter Bypass0ms
Long RunBattery Number 3 pcs 6 pcs 8 pcs 3 pcs 6 pcs 8 pcs
Maximum recovery voltageMaximum switching voltage-10V
Maximum switching voltage300VACI3 %
Minimum recovery voltageMinimum switching voltage +10V
ModelWall-mounted type Vertical type
Model NO.CYE2K
Noiseless than 50dB@1Meter
Operating Altitude< 1000m""
Operating Moisture< 95%And no condensation
Operating Temperature0-40°C
Optional SNMPSupport for power management by SNMP administrator and web browser.
OriginChina
Output CapacitySmall Type
Output Voltage208/220/230/240VAC
Output Voltage AccuracyI1%
OverloadAC Mode 30min@102%-110%Ioad, 10min@110%-130%load 30s@130%-150%Ioad, 500ms@>150 %Ioad
PhaseSingle Phase
Power1600w
Power Factor100% load z0.99
Product TitleNew Silu UPS Uninterruptible Power Supply Cye2K Online 2000va/1600W Built-in Battery Mh12V7ah * 4, Server Voltage Regulation, Power Outage, Silent 220V
ProtectionSealed Maintenance Free
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secure paymentsEvery payment you make on Made-in-China.com is protected by the platform.
Shipping Cost.
Size450*192*335mm
SmartRS- 232Suppon Windows@2000/2003/XP/Vista/2008. Windows@7/8, Linux. Unix and MAC
Specification450*192*335MM
StandardBattery Number 2 pcs 4 pcs 6 pcs 2 pcs 4 pcs 6 pcs
Standby TimeLong-acting Machine
Standby UPSSine Wave Output UPS
Switching timeMains Battery Oms
Temperature40°c
TrademarkNICEA
Transport PackagePaper Box with Wooden Box
TypeOn-line
Voltage220v
Voltage RangeMinimum switching voltage At 50% load, 11OVAC +3%;at 100% load, 176VAC+3 %
Warning CodeEnglish Meaning Linked Active Triggering Conditions Recovering Conditions

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

New Silu UPS Uninterruptible Power Supply Cye2K Online 2000va/1600W Built-in Battery Mh12V7ah * 4, Server Voltage Regula...

This detail page turns one product record into a narrower sourcing decision with clearer category fit, adjacent routes and RFQ-ready context.

Category
Lithium Battery Systems
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Product detail to shortlist decision
Primary compare
Category, Brand, Unit
Record focus
New Silu Ups Uninterruptible Power Supply Cye2k Online 2000va/1600w Built In Battery Mh12v7ah * 4, Server Voltage Regulation, Power Outage, Silent 220v
Category focus
Traffic Safety Facilities
Buyer checklist
  • Category fit: Confirm whether the product belongs to the right category and nearby application path before outreach.
  • Specification depth: Review the visible specifications and convert missing fields into a clearer RFQ requirement set.
  • Route expansion: Use adjacent category, solution and procurement routes before settling on one detail page.
How should buyers use this detail page?

Use the detail page as a product-fit checkpoint. Confirm category placement, visible specifications and adjacent sourcing paths before sending an RFQ.

What should buyers compare first?

Compare the visible specifications, category fit and the nearest application or solution routes before asking for supplier options.

PowerStackHub related sourcing paths

PowerStackHub procurement phrases

PowerStackHub project-fit checks

Application Confirm Application before comparing offers or moving the inquiry forward.
Country Confirm Country before comparing offers or moving the inquiry forward.
Capacity Confirm Capacity before comparing offers or moving the inquiry forward.
Material Confirm Material before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerStackHub related product samples

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions